in Row Cooling System

Send Inquiry
in Row Cooling System
Details
The In Row Cooling System is an in-row cooling unit designed for modular data centers. It is installed directly between server cabinet rows. This placement puts the cooling source right next to the heat load.
Category
Cabinet Air Conditioner
Follow us & Contact us
Description
Efficient Cooling for Modular Data Centers

The In Row Cooling System is an in-row cooling unit designed for modular data centers. It is installed directly between server cabinet rows. This placement puts the cooling source right next to the heat load. The product eliminates the long-distance air delivery that wastes energy in traditional room cooling. It uses front-discharge/rear-return or horizontal airflow patterns. These patterns create efficient airflow coupling with the cabinet equipment. The product reduces the return air path by over 80% compared to room-based systems. This reduction significantly lowers fan energy consumption. We have deployed this product in over 100 data centers including cloud computing facilities and HPC clusters. Our operational data shows that this product supports rack power densities up to 15kW per cabinet.

Redundant Design for Maximum Reliability

The In Row Cooling System includes redundant EC centrifugal fans and pluggable compressor modules. This design supports online maintenance without interrupting cooling. Even if one fan or compressor module fails, the remaining modules continue to operate. This product uses fuzzy logic PID algorithms. The control system adjusts cooling output based on actual cabinet inlet temperatures. This allows the product to deliver cooling on demand. We customize the unit width, height, and cooling capacity to match your specific aisle layout. The product is available in cooling capacities from 15kW to 40kW. We also offer N or N+1 redundancy levels based on your criticality requirements.

Seamless Building Management Integration

The In Row Cooling System supports multiple communication protocols. Standard options include RS485/Modbus and BACnet. We can also integrate with SNMP for network monitoring. Our engineering team completes communication protocol testing within 12 hours of receiving your BMS specifications. The product includes a user-friendly touchscreen interface on the front panel. This interface shows real-time operating parameters, alarm logs, and maintenance reminders. We manufacture this product with a heavy-duty steel chassis and customizable RAL colors. Every unit undergoes a full factory test, including 48-hour continuous operation at design conditions. The In Row Cooling System is backed by a one-year warranty and our experienced global support team.

Specifications

Parameter

Unit

Reference Value

Cooling Capacity

kW

15 to 40

Airflow Pattern

-

Horizontal / Front discharge with rear return

Power Supply

V/ph/Hz

380/3/50

Compressor Type

-

Hermetic Scroll (redundant configuration available)

Fan Type

-

EC centrifugal (redundant configuration available)

Communication Interface

-

RS485/Modbus/BACnet

Dimensions (W×D×H)

mm

Standard in-row dimensions, customizable per project