Electrical Enclosure Cooling Unit

Send Inquiry
Electrical Enclosure Cooling Unit
Details
The electrical enclosure cooling unit is used to reduce the internal temperature of electrical control cabinets. Suni SAH series covers 600 W to 3200 W. It uses wall-mounted installation. It is used for industrial electrical cabinets, variable frequency cabinets, and servo cabinets.
Category
Cabinet Air Conditioner
Follow us & Contact us
Description
Cooling Capacity and Air Flow

Model

Cooling Capacity

Cabinet Internal Air Flow

Cabinet External Air Flow

SAH600

600 W

120 m³/h

180 m³/h

SAH1000

1000 W

120 m³/h

180 m³/h

SAH1500

1500 W

150 m³/h

230 m³/h

SAH2000

2000 W

150 m³/h

230 m³/h

SAH2500

2500 W

230 m³/h

290 m³/h

SAH3200

3200 W

230 m³/h

290 m³/h

Buyers can select according to total heat generation of inverters, servo drives, PLCs, and other components in the cabinet.

System and Protection

System pressure hold: 26 bar.
Refrigerant: R22/R134A.
Power supply: 220V/1/50Hz.
Protection level: SAH600 to SAH2500 internal and external IP54. SAH3200 is IP55.

Specifications

Parameter

Unit

SAH600

SAH1000

SAH1500

SAH2000

SAH2500

SAH3200

Input power

W

287

300

330

340

420

450

Noise

dB(A)

55

55

55

55

60

60

Weight

kg

15

16

17

18

26

27

Dimensions (W×H×D)

mm

287×446×185

287×446×185

287×500×185

287×500×185

350×630×205

350×630×205

 

Customization
  • Power supply: 220V/1/50Hz (other specifications negotiable)
  • Refrigerant type: R22, R134A
  • Dimensions and color (batch orders)
  • Brand logo and nameplate
  • Protection level adjustment (by project requirement)
  • Export packaging marking and manual language

 

FAQ

Q: What is the difference between an electrical enclosure cooling unit and an electrical cabinet cooler?

A: Both have the same function, used for electrical cabinet internal temperature control. A cooling unit usually refers to a model with higher integration, possibly including a temperature control module or remote monitoring interface. A cooler usually refers to a single refrigeration unit. Specific configuration can be stated at inquiry.

Q: Can multiple electrical enclosure cooling units be connected in parallel?

A: Yes. If single cabinet heat generation exceeds 3200 W, or multiple cabinets need centralized cooling, multiple SAH series units can be combined. Configuration needs to be confirmed according to cabinet quantity, total heat generation, and installation space. Provide cabinet layout drawing and heat generation list.

Hot Tags: electrical enclosure cooling unit, China electrical enclosure cooling unit manufacturers, suppliers, factory, cabinet air conditioner thermostat, cabinet mounted air conditioner, control enclosure cooling air conditioner, electrical enclosure air conditioner, enclosure air conditioning unit, sealed cabinet air conditioner