Parameter |
Value |
|
Cabinet internal temperature range |
+25°C to +38°C |
|
Cabinet external temperature range |
-5°C to +55°C |
|
Protection level |
IP54/IP55 |
|
Power supply |
220V/1/50Hz |
|
Input power |
287 W to 610 W |
The internal temperature range is suitable for servers, storage equipment, and network equipment. The external temperature range covers edge computer rooms and industrial sites.
|
Model |
Cooling Capacity |
Cabinet Internal Air Flow |
Cabinet External Air Flow |
|
SAS300 |
300 W |
120 m³/h |
180 m³/h |
|
SAS1200 |
1200 W |
250 m³/h |
540 m³/h |
For server racks with high equipment density, select a model with larger air flow. For rack heat generation above 1200 W, select SAH series electrical cabinet cooler or combine multiple units.
|
Parameter |
Unit |
SAS300 |
SAS500 |
SAS800 |
SAS1200 |
|
Cooling capacity |
W |
300 |
500 |
800 |
1200 |
|
Power supply |
V/ph/Hz |
220/1/50 |
220/1/50 |
220/1/50 |
220/1/50 |
|
Refrigerant |
- |
R22/R134A |
Same |
Same |
Same |
|
Protection level (internal/external) |
IP |
IP54/IP54 |
IP54/IP54 |
IP54/IP54 |
IP55/IP54 |
|
Noise |
dB(A) |
55 |
55 |
60 |
65 |
Suni supports OEM/ODM cooperation. Server rack cooling units can be customized according to customer rack dimensions, equipment heat generation, and installation method. Cooling capacity, power supply, protection level, dimensions, and brand logo can be adjusted.
Minimum order quantity is 10 units. Samples can be provided but are charged separately. Inquiries, model confirmation, and quotation are answered within 12 hours.
Customizable Items
- Brand logo and nameplate
- Cooling capacity (matched to rack heat generation)
- Power supply (220V/1/50Hz and others)
- Protection level (IP54/IP55)
- Dimensions and installation method
- Refrigerant type (R22/R134A)
- Export packaging marking and manual language
Q: Can this unit be used for high-density server racks?
A: It depends on total equipment heat generation in the rack. SAS series single unit cooling capacity is up to 1200 W. If total heat generation exceeds 1200 W, select SAH series electrical cabinet cooler or combine multiple units. For high-density racks, provide equipment list and heat generation for technical calculation.
Q: What is the difference between a server rack cooling unit and an air conditioned rack enclosure?
A: Both have the same function, used for rack internal temperature control. A product usually targets high heat generation server rack scenarios. An air conditioned rack enclosure usually integrates the refrigeration unit with the rack structure. Selection depends on rack type and heat generation.
Hot Tags: server rack cooling unit, China server rack cooling unit manufacturers, suppliers, factory, cabinet air conditioner temperature controller, control cabinet cooling system, Dc Cabinet Air Conditioner, enclosure air conditioning unit, industrial cabinet air conditioner, Outdoor Cabinet Air Conditioner