Air Conditioned Rack Enclosure

Send Inquiry
Air Conditioned Rack Enclosure
Details
The product combines a refrigeration unit with a rack structure. It is used for internal temperature control of server racks, network racks, and equipment racks. Suni SAS series covers 300 W to 1200 W. It can use wall-mounted or rack-mounted installation. It is used for data center edge racks and industrial equipment racks.
Category
Cabinet Air Conditioner
Follow us & Contact us
Description
Cooling and Air Flow

SAS300 to SAS1200 includes 8 models. Cooling capacities are 300, 400, 450, 500, 600, 800, 1000, and 1200 W. Buyers can select according to total heat generation of servers, network equipment, and industrial computers in the rack.

Model

Cabinet Internal Air Flow

Cabinet External Air Flow

SAS300

120 m³/h

180 m³/h

SAS1200

250 m³/h

540 m³/h

For racks with high equipment density, select a model with larger air flow to ensure sufficient air circulation inside the cabinet.

Protection and Power

Protection level: SAS300 to SAS1000 internal and external IP54. SAS1200 is IP55.
Power supply: 220V/1/50Hz. Input power: 287 W to 610 W.
For rack mains power supply, no additional three-phase power is required.

Specifications

Standard Configuration

Parameter

Unit

SAS300

SAS500

SAS800

SAS1200

Cooling capacity

W

300

500

800

1200

Cabinet internal temperature range

°C

+25 to +38

+25 to +38

+25 to +38

+25 to +38

Cabinet external temperature range

°C

-5 to +55

-5 to +55

-5 to +55

-5 to +55

Power supply

V/ph/Hz

220/1/50

220/1/50

220/1/50

220/1/50

Refrigerant

-

R22/R134A

Same

Same

Same

Protection level (internal/external)

IP

IP54/IP54

IP54/IP54

IP54/IP54

IP55/IP54

Noise

dB(A)

55

55

60

65

 

Customization
  • Power supply: 220V/1/50Hz (other specifications negotiable)
  • Refrigerant type: R22, R134A
  • Dimensions and color (batch orders)
  • Brand logo and nameplate
  • Protection level adjustment (by project requirement)
  • Export packaging marking and manual language

 

FAQ

Q: What is the difference between an air conditioned rack enclosure and a standard cabinet air conditioner?

A: Both have the same function, used for rack internal temperature control. An air conditioned rack enclosure usually integrates the refrigeration unit with the rack structure and can be installed directly on a standard rack. A standard cabinet air conditioner usually uses wall-mounted installation on the side or front of the cabinet. Selection depends on rack type and installation space.

Q: Can this unit be used for a server rack?

A: Yes. SAS series cabinet internal temperature range is +25°C to +38°C, suitable for servers, network equipment, and other electronic equipment. Selection requires confirming total equipment heat generation, rack sealing condition, and installation space. If rack heat generation exceeds 1200 W, select SAH series electrical cabinet cooler.

Hot Tags: air conditioned rack enclosure, China air conditioned rack enclosure manufacturers, suppliers, factory, cabinet air conditioner filter, cabinet air conditioner temperature controller, dustproof cabinet air conditioner, high temperature cabinet air conditioner, industrial enclosure air conditioner, network cabinet air conditioner